At the U.S. average price of 18.16¢ per kWh. Your state's price changes these numbers; use the calculator.
Work out your cost
Change any number. The price per kWh is on your electric bill.
Starts at the U.S. average residential price, 18.16¢/kWh (August 2026, EIA, checked Oct 24, 2026). Month is 30 days; year is 12 such months.
The formula
cost = watts × hours ÷ 1,000 × price per kWh
Worked example: 2,940 W × 8 h ÷ 1,000 = 23.52 kWh a day. 23.52 kWh × $0.1816 = $4.27 a day, or about $128 over 30 days.
How many watts does a central air conditioner use?
Most are rated 1,500 to 4,970 W. The outdoor unit's nameplate and the maker's spec sheet give the size. In Goodman's model numbers, for example, 36 means 36,000 BTU/h (3 tons). Expanded cooling data in the spec sheet lists kW by outdoor temperature.
- Goodman's GSXN4 specification sheet (a 14.3 SEER2 single-stage split system) lists total system power at the AHRI rating point of 95°F outdoors, 80°F indoors and 67°F wet bulb: 1.50 kW for the 1.5-ton model (17,900 BTU/h of cooling), 2.94 kW for the 3-ton model (35,000 BTU/h) and 4.97 kW for the 5-ton model (57,500 BTU/h).
- Power rises as it gets hotter outside while cooling output falls. The same 3-ton system draws 2.66 kW at 85°F, 3.26 kW at 105°F and 3.64 kW at 115°F, and its output drops from 35,000 BTU/h at 95°F to 31,300 BTU/h at 115°F.
- A ton of cooling is 12,000 BTU/h, so the nominal sizes run from 18,000 BTU/h (1.5 tons) to 60,000 BTU/h (5 tons).
- The hours that matter are hours the compressor actually runs. A system set to cool all day cycles on and off, so 8 hours of run time can mean a whole hot day switched on.
- EIA's 2020 Residential Energy Consumption Survey puts average use at 2,318 kWh a year for air conditioning plus 457 kWh for the air handler in cooling mode, per home that uses them. The survey covers central and room units and evaporative coolers.
Cost at different electricity prices
| Use | Nevada (lowest state)12.72¢/kWh | U.S. average18.16¢/kWh | New York28.65¢/kWh | California29.75¢/kWh | Hawaii (highest state)47.18¢/kWh |
|---|---|---|---|---|---|
| 1.5-ton system at 95°F (1,500 W), 8 h/day360 kWh a month | $45.79$550/yr | $65.38$785/yr | $103$1,238/yr | $107$1,285/yr | $170$2,038/yr |
| 3-ton system on an 85°F day (2,660 W), 6 h/day479 kWh a month | $60.90$731/yr | $86.95$1,043/yr | $137$1,646/yr | $142$1,709/yr | $226$2,711/yr |
| 3-ton system at 95°F (2,940 W), 8 h/day706 kWh a month | $89.75$1,077/yr | $128$1,538/yr | $202$2,426/yr | $210$2,519/yr | $333$3,995/yr |
| 3-ton system in a 105°F heat wave (3,260 W), 12 h/day1,174 kWh a month | $149$1,791/yr | $213$2,558/yr | $336$4,035/yr | $349$4,190/yr | $554$6,644/yr |
| 5-ton system at 95°F (4,970 W), 12 h/day1,789 kWh a month | $228$2,731/yr | $325$3,899/yr | $513$6,151/yr | $532$6,387/yr | $844$10,130/yr |
Per month (30 days) and per year (12 such months). Real use is usually seasonal. Average residential prices for August 2026 from the same EIA table. Your utility's rate, including delivery charges, may differ. Check the price per kWh on your bill.
Ways to pay less
- Set it at 78°F, not 72°F DOE says running the AC at 78°F instead of 72°F saves 6 to 18% on the cooling bill. On a 3-ton system running 8 hours a day ($128 a month), that is about $7.69 to $23.06 a month. Raise the setting further when you're asleep or away.
- Pair it with a ceiling fan ENERGY STAR says raising the thermostat by 2 degrees and running a ceiling fan can cut air conditioning costs by up to 14%. DOE puts the comfortable increase at about 4°F. A certified fan on high costs about half a cent an hour, so switch it off when you leave the room.
- Check the filter every month DOE and ENERGY STAR both suggest checking or changing the filter monthly in cooling season. A dirty filter slows airflow and makes the system run longer, and ENERGY STAR says airflow problems can cut a system's efficiency by up to 15%.
- Book the tune-up for spring ENERGY STAR recommends a contractor check of the cooling system each spring, before contractors get busy: clean the indoor and outdoor coils, check the refrigerant charge and adjust the blower. Dirty coils make the system run longer for the same cooling.
- Size it right when you replace it DOE notes that an oversized air conditioner performs less efficiently than a smaller, properly sized one, so ask for a load calculation. ENERGY STAR certified split systems are rated at least 15.2 SEER2 and 12.0 EER2.
Safety. Leave refrigerant and electrical work on the outdoor unit to a licensed HVAC contractor. ENERGY STAR notes that faulty electrical connections can cause unsafe operation and shorten the life of major components, and that a plugged condensate drain can cause water damage in the house.
Questions
How much does it cost to run central air for an hour?
At 18.16¢/kWh (EIA, August 2026), about $0.27 an hour for a 1.5-ton system, $0.53 for a 3-ton system and $0.90 for a 5-ton system on a 95°F day, using Goodman's GSXN4 ratings. On an 85°F day the 3-ton system costs about $0.48 an hour; at 105°F, about $0.59.
How much does central air cost per month in summer?
For a 3-ton system at 95°F, about $64.07 a month at 4 hours of run time a day, $128 at 8 hours and $192 at 12 hours, at the U.S. average price. The 8-hour figure is about $89.75 at Nevada's 12.72¢/kWh and about $333 at Hawaii's 47.18¢/kWh.
How much does it cost to run the AC all night?
Eight hours of run time from a 3-ton system at 95°F uses 23.52 kWh, about $4.27 at 18.16¢/kWh. Nights are usually cooler, so the compressor runs fewer hours and draws less power per hour (2.66 kW at 85°F), which brings the real figure down.
Does central air conditioning use a lot of electricity?
Yes. Air conditioning was the largest single use of electricity in U.S. homes in 2020, at 19% of residential electricity (EIA). An hour of a 3-ton system at 95°F uses 2.94 kWh, about as much as two hours of a 1,500 W space heater on high.
Is it worth replacing an old central air conditioner?
Often, if it is past 12 years old: ENERGY STAR says a certified replacement could cut cooling costs by 30%. DOE's federal buying guide estimates that a 3-ton system in hot-humid states uses 9,159 kWh a year at 13.4 SEER2 and 8,074 kWh at the ENERGY STAR level of 15.2 SEER2. At 18.16¢/kWh that is $1,663 against $1,466, about $197 a year saved. In northern states the same comparison saves about $98.61 a year.
Does a home bitcoin miner raise my air conditioning bill?
Yes, in summer, because all of its power ends up as heat in the room. An 800 W Avalon Mini 3 gives off about 2,730 BTU/h. Goodman's 3-ton system removes 35,000 BTU/h on 2.94 kW at 95°F, so taking out the miner's heat costs about 229 W of extra AC power while both run. Around the clock that is about 165 kWh, or $29.98, on top of the miner's own $104.60 for 30 days at 18.16¢/kWh. At the November 19, 2026 hashprice the miner earns back about 31% of its own electricity, so its net cost rises from about $72.12 to $102 a month. Mining income moves with the bitcoin price and network difficulty; our bitcoin heater page recalculates it daily.
Sources
- U.S. EIA: Electric Power Monthly, Table 5.6.A: Average price of electricity by state, August 2026 (released Oct 23, 2026). Used for: U.S. average residential rate (18.16¢/kWh) and state rates
- Goodman: GSXN4 split system air conditioner specification sheet (SS-GSXN4, 14.3 SEER2, 1.5 to 5 tons). Used for: Expanded cooling data: total system kW and capacity by outdoor temperature (1.5-ton 1.50 kW, 3-ton 2.94 kW, 5-ton 4.97 kW at 95°F; 3-ton 2.66 kW at 85°F, 3.26 kW at 105°F, 3.64 kW at 115°F); nominal capacities
- U.S. EIA: 2020 Residential Energy Consumption Survey, Table CE5.3a (household site electricity end-use consumption, averages). Used for: 2,318 kWh a year for air conditioning and 457 kWh for air handlers in cooling, per household using the end use
- U.S. EIA: Electricity use in homes (Energy Explained). Used for: Air conditioning was 19% of residential electricity in 2020; 67% of homes have central air
- U.S. DOE, Federal Energy Management Program: Purchasing energy-efficient residential central air conditioners. Used for: Annual kWh for a 36,000 BTU/h system at 13.4 and 15.2 SEER2 in hot-humid and northern states
- U.S. DOE: Top 11 things you didn't know about saving energy at home, summer edition. Used for: 78°F instead of 72°F saves 6 to 18% on the cooling bill
- U.S. DOE: Energy Saver guide (2022, PDF). Used for: Ceiling fan lets you raise the thermostat about 4°F; clean or replace AC filters monthly; oversized units perform less efficiently; raise the setting when asleep or away
- ENERGY STAR: Keep cool and comfy with ENERGY STAR (cooling fact sheet, 2020, PDF). Used for: Check filters monthly; replacing a unit over 12 years old could cut cooling costs 30%; 2 degrees plus a ceiling fan saves up to 14%
- ENERGY STAR: Maintenance checklist. Used for: Spring cooling check-up, coils, refrigerant, airflow problems cut efficiency up to 15%, electrical connections, condensate drain
- ENERGY STAR: Program requirements version 6.2, central air conditioners and air-source heat pumps (PDF). Used for: Certified split systems at least 15.2 SEER2 and 12.0 EER2
- WattCost: hashprice (mempool.space and CoinGecko), November 19, 2026, and Canaan Avalon Mini 3 specifications. Used for: Avalon Mini 3: 37.5 TH/s at 800 W; mining income at $28.87 per PH/s a day (page blocks some automated checks; specs also used on our crypto mining and ceiling fan pages)